DM4 Applications:
DM4 Dual Digital Micro-Manometer Specifications
| Feature | Specifications |
| Sensors: | 2 independent differential pressure transducers with auto zeroing |
| Pressure Resolution: |
Display resolution in the Pascal mode is 0.1 Pa from 0.0 Pa to ±999.9 Pa and 1 Pa from 1000 Pa to ±1250 Pa. Display resolution in the US units mode is 0.001 "wc from 0.000 "wc to ±5.000 "wc. Internal resolution is 0.025 Pa or 0.0001 "wc over the entire ±5.000 "wc (±1250 Pa) range. and this is the resolution of the serial output. |
| Pressure Range: |
Bi-directional: ±5.0 "wc (±1250 Pa). For higher pressures, see the Infiltec DM5. |
| Keys: | 7 function selection keys. |
| - Device Key: | Select: Manometer, Pitot tube, E3 blower door, DL1 duct tester, G54 mobile fan devices. |
| - Units Key: |
Dual Manometer: Metric (Pa, Pa), U.S. ("wc, "wc), Mixed ("wc, Pa) Pitot flow: Metric (Pa, m/s), U.S. ("wc, f/m), Mixed (Pa, fpm) Infiltec E3 blower door flow: Metric (Pa, m3/h), U.S. ("wc, cfm), Mixed (Pa, cfm) Infiltec E3 blower door ELA (leakage area): Metric (Pa, cm2), U.S. ("wc, in2), Mixed (Pa, in2) Minneapolis Model 3 blower door flow: Metric (Pa, m3/h), U.S. ("wc, cfm), Mixed (Pa, cfm) Minneapolis Model 3 blower door ELA (leakage area): Metric (Pa, cm2), U.S. ("wc, in2), Mixed (Pa, in2) Infiltec DL1 duct tester flow: Metric (Pa, m3/h), U.S. ("wc, cfm), Mixed (Pa, cfm) Infiltec DL1 duct tester ELA (leakage area): Metric (Pa, cm2), U.S. ("wc, in2), Mixed (Pa, in2). |
| - Time Avg Key: | Select block average of 1 (default), 2, 4, 8, 16, 32 or 64 seconds. |
| - Low Flow Key: |
Dual Manometer: no function Pitot tube flow: no function Infiltec E3 blower door low flow plate: Off, CRF (Can't reach 50 Pa), 7 holes open, 5 open, 3 open, 2 open, 1 open Minneapolis Model 3 blower door low flow rings: Off, CRF (Can't reach 50 Pa), A Ring, B Ring, C Ring Infiltec DL1 duct tester orifice tubes: Off, 16 cm2 tube on, 4 cm2 tube on, 1 cm2 tube on |
| - Baseline Key: | Resets the zero building pressure for Infiltec E3 or Minneapolis Model 3 blower door calculations. |
| - Hold Key: | Holds reading on display until pressed again. |
| - On/Off Key: | Turn power on and off. |
| Accuracy: |
Dual Pressure: ±1% of display measurement or ±1 digit, whichever is greater. Pitot Flow: ±1.5% of measurement or better from 800-6900 fpm (4-35 m/s) Infiltec E3 blower door flow or ELA: ±1.5% of measurement or better Minneapolis Model 3 blower door flow or ELA: ±1.5% of measurement or better Infiltec DL1 duct leakage flow or ELA: ±1.5% of measurement or better |
| Display Type: | 2x16 high contrast LCD with numbers and characters. |
| Operating Temperature: | 32°F to 122°F. (0°C to 50°C) |
| Storage Temperature: | -4°F to 160°F. (-20°C to 70°C) |
| Maximum Pressure: | ±25 "wc, ±6 kPa or ±0.9 PSI |
| Low Battery Display: |
Current battery voltage is displayed at startup, "lowbat" displayed when voltage is under 7 volts. |
| Over Range Indicator: | !!MAX!! displayed when pressure is beyond range ±5.000 "wc (±1250 Pa). |
| Auto Zero: | Pneumatic switches update zero pressure estimates every 10 seconds. |
| Weight With Battery: | ~16 oz. (~455 grams) |
| Dimensions: | 4.0"x7.5"x1.79" (101.6x190.5x45.4 mm). |
| Battery Life: | Over 100 hours from six AA alkaline batteries. |
| Operating Medium: | Air or non-corrosive, non-explosive gas. |
| Pressure Connections: | Two pairs, barbed for 1/8" ID tubing. |
| Serial Output: |
9600-8N0 pseudo RS232 ASCII records at 1 Hz with LF+CR termination ±50000 range, 0.025 Pa resolution, comma separates two channel values |
| Microprocessor: |
Embedded firmware with serial programmable calibration constants. |
| Custom Firmware: |
Infiltec can modify the DM4 firmware with your fan calibration constants. |
| Optional Accessories: | E3 blower door, DL1 duct tester, Pitot tube, serial cable, 110 VAC or 220 VAC power adaptor. |
| Accessories Included: | Battery, soft carrying case, tubing, calibration certificate, user manual. |
| Warranty: | 2 years coverage on parts and labor to repair any defects. |
For current DM4 prices, see the Infiltec Radon or Blower Door catalogs, or call (540) 943-2776 weekdays 7AM-4PM ET.
![]()