USER INSTRUCTIONS FOR INFILTEC LEAKAGE ANALYSIS PROGRAM FIREDEMO.EXE is a self extracting file that contains the DOS multi-gas program LA.COM with sample data files for most gases. Save the extracted files to a new folder such as c:\firedemo on your hard drive, or onto a floppy disk folder. After saving the program files, you can run the program by going to START then RUN then C:\firedemo\LA.COM. LA.COM is the program file. The LA.COM program prints to DOS LPT1 printer, but this may not work under Windows. To get around this, you can select the printout option "Print to File" and the report will be saved in a text file so that you can use a word processing program like MS Word to print your report. You will want to select a mono-spaced font like courier for these reports, and not a proportional spaced font, to keep the formatting of the data columns straight. The sample test files for each gas are adapted from the NFPA 12A-1989 Standard Appendix B on Integrity Testing for Halon 1301 Total Flooding Fire Suppression Systems NOTE: To use this software with E3-DM4 you MUST: 1. Set Orifice Plate Ratio=1.0 in this program because the DM4 computes the ratio from the Low Flow settings. 2. For depressurization (fan blowing away from you) leave both DM4 reference ports open. Connect the signal ports to the fan and the door panel. For pressurization (fan blowing way from you) leave the pressure reference port open, but connect the flow reference port to outside/door pressure tap on the door with T fitting. Contect the signal ports to the fan and the door panel. If you have any questions about these two instructions, contact the Infiltec factory at 540-943-2776. Improvements in 06/20/94 Version of Program LA 1. NFPA 2001-94 based calculations for gases 1301, Inergen, FM-200, FE-13 and NAF-SIII. 2. The graph is printed out in the report on a separate page. 3. Printer output can be written to a disk file (in ASCII format) for use in word processing 4. The ESC key now allows jumping from all screens, back to the previous screen. 5. Printer output has 1" margins at left and right if your printer is set to 10 cpi. 6. More comment lines are added to Test Identification Screen. 7. If screen entries are blank, then the lines are not printed out in report. 8. Optional upper leakage area calculation shows the effect of changing ratio of upper to lower leakage. 9. Optional mixture density is computed from gas weight, room volume, and site altitude. Instructions for running Infiltec MSDOS Program LA * Make a copy of the program disk and store it in a safe place as a backup (e.g. COPY A:*.* B:). * You can copy the program disk onto your hard disk and run it from there (e.g. XCOPY A:*.* C:) * You must have file the LA.COM to run, plus HERC.COM if you have a mono graphics monitor. * To run from a floppy drive, insert the disk and log onto the drive (e. g. put it in drive A and get A>). * Type the program name, HA, and press the ENTER key to start program. * The first screen will ask you whether you want an "old" file with saved test data or start a "new" file. * If you can not read the first screen, press F1 to quit, and type LA S to restart. This will slow the display. * Type the letter O (for Old) to select an old file, so you can see some sample data. * The next screen shows a directory of test files that are saved on the disk such as NFPA-CAL.HAL * Type the first few letters (like N or NF) to select the file named NFPA-CAL and then press ENTER. * Type Y (for Yes) when you are asked if NFPA-CAL is the file that you wanted. * Files 1301, CO2, INERGEN, FE-13, CEA-410, NAF-SIII and FM-200 are examples. * File NFPA-CAL contains the NFPA 2001-94 sample calculation test data. * File README has information on latest updates to the program. * You can look through the data file you select by just pressing ENTER to move through screens. * Or you can use the arrow, page, insert and delete keys to edit lines. * Or you can use the function keys to jump around or change calculations: * F1 Key = Quit the program. Before quitting, you will be asked if you want to save your work on disk. * F2 Key = Change flow data input from flow units (cfm or lps) to flow pressure units (in wc or Pa). * F3 Key = Jump ahead to the next screen. ESC jumps you back to the previous screen. * F4 Key = Change the measurement units from metric (Pa & lps) to English (in wc & cfm) and back. * F5 Key = Save your work on a disk file that you can name and retrieve later. * F6 Key = Change the calculation type from "NFPA only" to "Infiltec & NFPA" and back. * F7 Key = Print a report of all data entered or computed up through the screen you are on, or you can save the report in a disk file for your word processor. Standard Program features: * Data can be easily saved and retrieved from small disk files. These files have a ".HAL" extension) * The program works with any video board: CGA, Hercules, EGA, VGA, etc. * Data editing uses all the standard keys: Insert, Delete, Page, Arrows, etc. * Function keys are used to jump between screens and to change modes. * Color is used on all screens, but the program also works on monochrome or LCD monitors. * You can switch from English to metric units (and back) by pressing key F4. Note that if you save a data file, the type of units will be saved, and the next time you display this data, the units will be the same as when you saved it. So if you always work in one set of units, you will not have to switch back and fourth if you do not want to. * Key F6 switches you between straight NFPA 2001-94 calculations and the Infiltec calculations. Note that NFPA calculations predict the hold time for 1/2 of the initial concentration (3% if you discharge 6%), while Infiltec has developed a prediction of the hold time for a 1% drop in the concentration (5% if you discharge 6%). Since the Infiltec calculations may be confusing to your customers who do not understand the NPFA calculations, you can stay in the NFPA mode during demonstrations, and then switch to the Infiltec mode when you need to have a better prediction of actual discharge test results. * When you exit the program, you are always asked to save your data so that valuable test results will not be lost. If you were editing a previous test file, you are given the option of overwriting the original file or creating a new file name. * The program is designed to be user friendly so that it is difficult to accidently make serious errors. Please give us your suggestions for improvements and let us know about any problems. Software and Manual Copyright 1989-2006 by INFILTEC PO Box 1125, Waynesboro, VA 22980 * Phone (540) 943-2776 * Fax (540) 932-3025